,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Broadcast Tubes,Transmitting Tubes,Transmitting,Broadcast,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">

GU-50 PENTODE

The GU-50 pentode is used as a RF oscillator and power amplifier in the metric wavelength range in RF equipment

GENERAL

Cathode: indirectly heated, oxide-coated.
Envelope: glass, no-base.
Height: at most 93.5 mm.
Diameter: at most 45.3 mm.
Mass: at most 100 g

OPERATING ENVIRONMENTAL CONDITIONS
Ambient temperature, °C -10 to +55
Relative humidity at up to +25 °C, % 98

BASIC DATA
Electrical Parameters
Heater voltage, V 12.6
Heater current, A 0.6-0.85
Mutual conductance (at anode voltage 800 V, grid 2 voltage 250 V, grid 1 voltage increment 5 V, anode current 50 mA), mA/V 3-5.5
Bias voltage at operating point, V 25-55
Penetration factor of grid 1 relative to grid 2, % 16-26
Interelectrode capacitance, pF:
input, at most 13-15
output, at most 10.3
transfer, at most 0.1
Output power, W, max.:
at anode voltage 800 V, grid 2 voltage 250 V, grid 1 voltage -100 V, anode current, at most 150 mA 55
over 1,750 h of service 40

Limit Operating Values
Heater voltage, V 11.3-13.9
Anode voltage at different wavelengths, V:
6.5 m or longer 1,000
6.5-4.5 m 800
4.5-3.5 m 700
3.5-2.5 m 600
Grid 2 voltage, V 250
Voltage between cathode and heater, V 200
Dissipation, W:
anode 40
grid 2 5
grid 1 1
Envelope temperature, °C 200

gu-50(2)1.jpg
Averaged Anode-Grid 2 Characteristic Curves:
Uf = 12.6V; Ug2 = 250V; Ug3 = 0

gu-50(2)2.jpg
Averaged Grid 2-Anode Characteristic Curves:
Uf = 12.6V; Ug2 = 250V; Ug3 = 0

gu-50(2)3.jpg
Averaged Characteristic Curves:
Uf = 12.6V; Ug2 = 500V; Ug3 = 0
_____ anode-grid;
- - - grid 2